CCTSST-FR0.3 n×1×1.4
Application
The cables are used as railway cables and can be installed directly into the ground or in ducts.
Standard
- RENFE E.T. 03.365.051.6
Cable Construction
- Conductors: Soft annealed solid copper, 1.4 mm nominal diameter.
- Insulation: PE insulation.
- Stranding: Cores are helically stranded in concentric layers.
- Core Wrapping: Two or more layers of plastic tape(s) with overlapping.
- Screen: Copper tapes with overlap (protection against interference).
- Inner Sheath: FRNC-PE sheath, coloured green.
- Armour: Two layers of steel tape (0.8mm thick).
- Outer Sheath: FRNC-PE sheath, coloured green.
Electrical Characteristics at 20℃
Nominal Conductor Diameter | mm | 1.4 |
Maximum Conductor Resistance | Ω/km | 11.7 |
Minimum Insulation Resistance @500 V DC | MΩ.km | 35000 |
Resistance Unbalance | % | 2 |
Test Voltage @50Hz 1min | ||
Core to Core | Veff | 2100 |
Core to Screen | Veff | 2500 |
Reduction Factor @100V/km 50Hz | 0.3 |
Mechanical and Thermal Properties
- Minimum Bending Radius: 10×OD
- Temperature Range: -40℃ to +60℃ (during operation); -10℃ +60℃ (during installation)
Dimensions and Weight
Cable Code | Number of Cores |
Nominal Sheath Thickness mm |
Maximum Overall Diameter mm |
Nominal Weight kg/km |
|
---|---|---|---|---|---|
Inner | Outer | ||||
1.4mm Conductor, 2.6mm Insulated Wire | |||||
RS/CCTSST-FR0.3-2Y(K)HBH-4C1.4 | 4 | 1.5 | 1.6 | 18.0 | 705 |
RS/CCTSST-FR0.3-2Y(K)HBH-19C1.4 | 19 | 1.6 | 1.8 | 26.1 | 1362 |
RS/CCTSST-FR0.3-2Y(K)HBH-27C1.4 | 27 | 1.6 | 1.8 | 29.2 | 1648 |
RS/CCTSST-FR0.3-2Y(K)HBH-48C1.4 | 48 | 1.7 | 1.8 | 36.7 | 2348 |